Art.Nr.:

Victron BatteryProtect Bp - 40I

Victron BatteryProtect Bp - 40I

Inclusief BTW (21%) Verzendinformatie*

Victron BatteryProtect Bp - 40I
logo-victron-medium.jpg
In de rubriek Victron vindt u de producten en prijzen van Victron. Een selectie Victron producten die u kunt kopen zoals een omvormer, omvormer lader, acculader, scheidingstransformator, dc-dc converter, transfer switch, lynx en dc distributie, zekeringen, ve net, remote paneel, esp, data kabel, interface, accu monitor, batterij isolator, walstroom kabel, solar laadregelaar, zonnepaneel, accu, agm, gel, grid inverter, lithium accu. Volledige fabrieksgarantie op de Victron producten. Verzenden of afhalen is mogelijk.

Tips en advies

De gerelateerde producten in de rubrieken Omvormer Lader en Acculader en Omvormer zijn voor u mogelijk ook interessant.

Contact

Heeft u een vraag. Neem contact met ons op per Email voor tips en advies over de Victron BatteryProtect Bp - 40I.

Specificaties

Victron Energy BatteryProtect BP-40i

Disconnect your loads before the battery is flat!

Disconnect your loads before the battery won’t start the engine any more!


The Victron Energy BatteryProtect disconnects the battery from non essential loads before it is completely discharged (which would damage the battery) or before it has insufficient power left to crank the engine.

12/24V auto ranging

The BatteryProtect automatically detects system voltage.

Fully programmable with simple ‘countdown’ program

The BatteryProtect can be set to engage / disengage at several different voltages with a simple ‘count down’ program.

Over voltage protection

To prevent damage to your sensitive loads due to over voltage, the load is disconnected whenever the DC voltage exceeds 16 V respectively 32 V.

Ignition proof

No relays but MOSFET switches, and therefore no sparks.

Delayed alarm output

The alarm output is activated if the battery voltage drops below the preset disconnect level during more than 15 seconds. Starting the engine will therefore not activate the alarm. The alarm output is an open collector output to the negative (minus) rail, max. current 500 mA. The alarm is typically used to activate a buzzer and / or lamp.

Delayed load disconnect

Only 1 minute after the alarm has been activated will the load be disconnected. If battery voltage increases to the connect threshold within this minute (after the engine has been started for example) the load will not be disconnected.

Features:
  • Maximum continuous load current: 40A
  • Peak current: 120A
  • Operating voltage range: 6 –35 V
  • Current consumption: 4mA
  • Alarm output delay: 15 seconds
  • Load disconnect delay: 1 minute
  • Default threshold - Disengage: 10,5V or 21V Engage: 12V or 24V
  • Weight: 0.2 kg
  • Dimensions (HxWxD) mm: 80 x 60 x 40